The impact of wire caliber on ERCP outcomes: a multicenter randomized controlled trial of 0.025-inch and 0.035-inch guidewires

2018
Background and Aims Wire-guided biliary cannulation has been demonstrated to improve cannulation rates and reduce post-ERCP pancreatitis (PEP), but the impact of wire caliber has not been studied. This study compares successful cannulation rates and ERCP adverse events by using a 0.025-inch and 0.035-inch guidewire. Methods A randomized, single blinded, prospective, multicenter trialat 9 high-volume tertiary-care referral centers in the Asia-Pacific region was performed. Patients with an intact papilla and conventional anatomy who did not have malignancy in the head of the pancreas or ampullaand were undergoing ERCP were recruited. ERCP was performed by using a standardized cannulation algorithm, and patients were randomized to either a 0.025-inch or 0.035-inch guidewire. The primary outcomes of the study were successful wire-guided cannulation and the incidence of PEP. Overall successful cannulation and ERCP adverse events also were studied. Results A total of 710 patients were enrolled in the study. The primary wire-guided biliary cannulation rate was similar in 0.025-inch and 0.035-inch wire groups (80.7% vs 80.3%; P = .90). The rate of PEP between the 0.025-inch and the 0.035-inch wire groups did not differ significantly (7.8% vs 9.3%; P = .51). No differences were noted in secondary outcomes. Conclusion Similar rates of successful cannulation and PEP were demonstrated in the use of 0.025-inch and 0.035-inch guidewires. (Clinical trial registrationnumber: NCT01408264.)