The Energy calibration of LEP in the 1993 scan

1995 
This report summarizes the procedure for providing the absolute energy calibration of the LEP beams during the energy scan in 1993. The average beam energy around the LEP ring was measured in 25 calibrations with the resonant depolarization technique. The time variation of this average beam energy is well described by a model of the accelerator based on monitored quantities. The absolute calibration of the centre of mass energies of the off-peak points is determined with a precision of 2 parts in 105 resulting in a systematic error on the Z-mass of about 1.4 MeV and on the Z-width of about 1.5 MeV.