Porous-coated total hip replacement.

1994 
Fifteen years of clinical experience with porouscoated prostheses demonstrated the durability of this type of fixation. This experience was documented by clinical follow-up study of the 393 cases treated by the senior author before 1985. Only six of these femoral components have been revised: three for loosening, two for stem breakage, and one for infection. Thus, the revision rate for the porous-coated stems was 1.5%. Porous-coated acetabular components were used in 227 of the arthroplasties. Five of these porous-coated cups have been revised: four for malposition leading to dislocation and one for late loosening secondary to osteolysis. Thus, the revision rate for these porouscoated acetabular components was 2.2%