Use of Vivostat® Autologous Fibrin Sealant in Thyroid Surgery.

2021 
Introduction Post-thyroidectomy hemorrhage is a rare but potentially life-threatening and unpredictable complication of thyroid surgery. Therefore, intraoperative bleeding control and hemostasis are crucial. However, the most efficient, cost-effective, and standardized way to achieve this is not clear. This study aimed to evaluate the outcome of total thyroidectomy (TT) and partial thyroidectomy (PT) performed using the Vivostat® hemostatic system (Vivostat A/S, Lillerod, Denmark). Methods Patients underwent TT and PT for benign and malignant diseases (multinodular goiter, Graves' disease, differentiated thyroid carcinoma). The primary endpoint was 1st-day postoperative drain output and bleeding that required reintervention. Secondary endpoints included surgery duration and postsurgical complications (vocal fold palsy, hypocalcemia, seroma, wound infection). Results Between October 2020 and December 2020, 56 patients were enrolled; 69.6% female; mean age 49.5 years. The mean 24-h drain output was 40 ml. No redo surgery was needed. Seroma was present in 5.3% of cases; no permanent vocal palsy or hypocalcemia was observed. Conclusion This study shows that the Vivostat® system is both safe and effective for hemostasis during thyroid surgery.