Plasma temperature measurement with a silicon photomultiplier (SiPM)

2020
The temperature of a nonneutral plasma confined in a Penning–Malmberg trap can be determined by slowly lowering one side of the trap’s electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles escape the trap as a function of the barrier height. In many experiments, the escaping particles are directed toward a microchannel plate, and the resulting amplified charge is collected on a phosphor screen. The screen is used for imaging the plasma but can also be used as a Faraday cup (FC) for a temperature measurement. The sensitivity limit is then set by microphonic noise enhanced by the screen’s high-voltage bias. Alternately, a silicon photomultiplier (SiPM) can be employed to measure the charge via the light emitted from the phosphor screen. This decouples the signal from the microphonic noise and allows the temperature of colder and smaller plasmas to be measured than could be measured previously; this paper focuses on the advantages of a SiPM over a FC.