The effect of temperature gradients in thermo-mechanical fatigue testing

2019 
AbstractThe focus of this paper is the characterization of the influence of the temperature rates on the TMF lives. Therefore static and the dynamic calibrations of the temperature measurement devices were compared by a custom-built calibration specimen, which included five internal mantle thermocouples. Additionally the temperatures were measured on the specimens’ surface. The experimental setups used were compared by executing TMF pre-test with the identical single-crystalline specimen. Subsequently TMF tests on coated single-crystalline Nickel-based superalloy PWA 1484 were carried out with temperature rates of 10K/s and 20K/s . Finally the deviations of the determined TMF lives were evaluated.