Aging tests of full-scale CMS muon cathode strip chambers

2003
Two CMS production Cathode Strip Chambers were tested for aging effects in the high radiation environment at the Gamma Irradiation Facility at CERN. The chambers were irradiated over a large area: in total, about 2.1 m{sup 2} or 700 m of wire in each chamber. The 40% Ar+50%CO{sub 2}+10%CF{sub 4} gas mixture was provided by an open-loop gas system for one of the chambers and by closed-loop recirculating gas system for the other. After accumulating 0.3-0.4 C per centimeter of a wire, which is equivalent to operation during about 30-50 years at the peak LHC luminosity, no significant changes in gas gain, chamber efficiency, and wire signal noise were observed for either of the two chambers. The only consistent signs of aging were a small increase in dark current from {approx}2 nA to {approx}10 nA per plane of 600 wires and a decrease of strip-to-strip resistance from 1000 G{Omega} to 10-100 G{Omega}. Disassembly of the chambers revealed deposits on the cathode planes, while the anode wires remained fairly clean.