Measurement of Radiation Losses and Effective Ion Charge on the Globus-M2 Tokamak

2021 
In this Letter, results of measurements of radiation losses Prad and effective ion charge Zeff in the conditions of magnetic field up to 0.7 T and plasma current up to 300 kA for a wide range of electron density first obtained on the Globus-M2 tokamak are presented. The analysis of the results shows the decrease in the radiation losses share of the input power on the Globus-M2 tokamak as compared with the same parameter for the Globus-M facility. A large dip at the center of the Prad power profiles is revealed. A decrease in the Zeff values is observed with an increase in electron density.