Impact of slice thickness on clinical utility of automated Alberta Stroke Program Early Computed Tomography Scores

2020 
The clinical utility of electronically derived ASPECTS (e-ASPECTS) to quantify signs of acute ischemic infarction could be demonstrated in multiple studies. Here, we aim to clinically validate the impact of CT slice thickness (ST) on the performance of e-ASPECTS software. A consecutive series of n = 258 patients (06/2016 and 01/2019) with middle cerebral artery occlusion and subsequent treatment with mechanical thrombectomy was analyzed. The e-ASPECTS score and acute infarct volumes were calculated from baseline non-contrast CT with a software using 1-mm slice thickness (ST) (defined as ground truth) and axial reconstructions with 2–10-mm ST and correlated with baseline stroke severity (NIHSS) as well as clinical outcome (mRS) using logistic regressions. In comparison with the ground truth, significant differences were seen in e-ASPECTS scores with ST > 6 mm (p ≤ 0.031) and infarct volumes with ST > 4 mm (p ≤ 0.001). There was a significant correlation of lower e-ASPECTS and higher acute infarct volumes with increasing baseline NIHSS values for all ST (p ≤ 0.001, respectively), with values derived from 1 mm yielding the highest correlation for both parameters (rho, − 0.38 and 0.31, respectively). Similarly, lower e-ASPECTS and higher acute infarct volumes from all ST were significantly associated with poor outcome after 90 days (p ≤ 0.05, respectively) with values derived from 1-mm ST yielding the highest effects for both parameters (OR, 0.69 [95% CI 0.50–0.88] and 1.27 [95% CI 1.10–1.50], respectively). The e-ASPECTS software generates robust values for e-ASPECTS and acute infarct volumes when using ST ≤ 4 mm with ST = 1 mm yielding the best performance for predicting baseline stroke severity and clinical outcome after 90 days. • Clinical utility of automatically derived ASPECTS from computed tomography scans was shown in patients with acute ischemic stroke and treatment with mechanical thrombectomy. • Thin slices (= 1 mm) had the highest clinical utility in comparison with thicker slices (2–10 mm) by having the strongest correlation with baseline stroke severity and independent effects on clinical outcome after 90 days. • Automatically calculated acute infarct volumes possess clinical utility beyond ASPECTS and should be considered in future studies.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    10
    References
    4
    Citations
    NaN
    KQI
    []
    Baidu
    map