TOMOGRAPHY OF A SEEDED FREE-ELECTRON LASER FOCAL SPOT: QUALITATIVE AND QUANTITATIVE COMPARISON OF TWO RECONSTRUCTION METHODS FOR SPOT SIZE CHARACTERIZATION

2021
Performing experiments at free-electron lasers (FELs) requires an exhaustive knowledge of the pulse temporal and spectral profile, as well as the focal spot shape and size. Operating FELs in the extreme ultraviolet (EUV) and soft X-ray (SXR) spectral regions calls for designing ad-hoc optical layouts to transport and characterize the EUV/SXR beam, as well as tailoring its spatial dimensions at the focal plane down to sizes in the few micrometers range. At the FERMI FEL (Trieste, Italy) this task is carried out by the Photon Analysis Delivery and Reduction System (PADReS). In particular, to meet the different experimental requests on the focal spot shape and size, a proper tuning of the optical systems is required, and this should be monitored by means of dedicated techniques. Here, we present and compare two reconstruction methods for spot characterization: single-shot imprints captured via ablation on a poly(methyl methacrylate) sample (PMMA) and pulse profiles retrieved by means of a Hartmann wavefront sensor (WFS). By recording complementary datasets at and nearby the focal plane, we exploit the tomography of the pulse profile along the beam propagation axis, as well as a qualitative and quantitative comparison between these two reconstruction methods.