CT differentiation of enlarged mediastinal lymph node due to anthracosis from metastatic lymphadenopathy: a comparative study proven by endobronchial US-guided transbronchial needle aspiration.
2015
RESULTS Malignant lymph nodes showed significantly greater axis diameters (P < 0.001). Both anthracotic and malignant nodes were most often oval (86.5% of all malignant nodes vs. 81.5% of all anthracotic nodes, P = 0.420) and showed confluence in a remarkable percentage (28.1% vs. 42.6%, P = 0.075). Anthracotic nodes showed calcifications more often (18% vs. 0%, P < 0.001). Malignant lymph nodes showed a significantly greater short and long axis diameter (P < 0.001), and they had a higher frequency of ill-defined contours (27.8% vs. 2.2%, P < 0.001) and contrast enhancement (27.8% vs. 5.6%, P < 0.001). Nodal necrosis, which appeared in one third of the malignant nodes, was not observed in anthracosis (35.2% vs. 0%, P < 0.001). Confluence of enlarged lymph nodes was seen in malignant lymph nodes (42.6%), as well as in lymph node enlargement due to anthracosis (28.1%, P = 0.075).