A quantitative comparison between using sodium hypochlorite as a digestion method for the diatom test and the conventional method using fuming nitric acid.

2021
OBJECTIVE To determine the efficacy of using sodium hypochlorite (NaClO, Purelox) as a simple and rapid alternative digestion method for the diatom test through a quantitative comparison with the conventional method that uses fuming nitric acid (HNO3). MATERIALS AND METHODS In experiment 1, using 30 water samples, the NaClO and HNO3 methods were compared using paired t-test. In experiments 2 and 3, we included blank human lung plus 13 water samples and total of 32 drowned human lung samples, respectively, to compare the NaClO and HNO3 methods using paired t-test. The relationship between the concentration ratio and background factors was tested in experiment 3. Welch's t-test was used to determine differences in the ratio between the lung side and sex, whereas Pearson's correlation coefficient was used to determine the correlation between the ratio and either age or postmortem interval. The geometric mean of two counts was used for each specimen and all counts were logarithmically transformed to base 2 in the statistical analysis. RESULTS The NaClO method was completed within 80 min for any sample. In experiment 1, there was no significant difference between the NaClO and HNO3 methods using water samples (the mean of the ratios: 0.99, 95% confidence interval (95%CI: 0.89-1.10, P = 0.80). In experiment 2, the count of the NaClO method was lower than that of the HNO3 method using lung plus water samples (the mean of the ratios: 0.47, 95% CI: 0.35-0.65, P = 0.0002). In experiment 3, the concentration of the NaClO method was lower than that of the HNO3 method using drowned lung samples (the mean of the ratios: 0.28, 95% CI: 0.20-0.38, P < 0.0001). A weak correlation between the postmortem interval and the ratio of the two methods was observed (r = -0.58, P = 0.012), although no difference between lung sides or sexes were detected (P = 0.87 and P = 0.50, respectively) and no correlation occurred between age and the ratio (r = 0.15, P = 0.43). CONCLUSION Using NaClO as a simple and rapid digestion method for diatom testing of water samples would be an excellent alternative to conventional methods. Although the method's diatom detection rate for the lung samples was not optimal, it was still shown to be a feasible method.
    • Correction
    • Source
    • Cite
    • Save
    23
    References
    0
    Citations
    NaN
    KQI
    []
    Baidu
    map